Versions Compared

Key

  • This line was added.
  • This line was removed.
  • Formatting was changed.


Image Added

conductor nodes are always run as active/active




create the hostname

prepare both IP address

need to be routable

Conductor Name:  xxxx

Node Name 

Image Added


If installing the SSR software for the first time, a system reboot is required.
On the GUI
Device interfacemode no-forwarding
Network interfacetype: fabric +  IP address ( prefix length and GW )

Image Added

full init config
node1 and node2


Code Block
titlenode1
collapsetrue
admin@conductornode1.conductoresxi# show config running

config

    authority



        router        conductoresxi
            name  conductoresxi

            node  conductornode1
                name              conductornode1
                asset-id          conductornode1

                device-interface  mgmt
                    name               mgmt
                    pci-address        0000:0b:00.0
                    forwarding         false

                    network-interface  mgmt-if
                        name        mgmt-if
                        global-id   1
                        type        fabric
                        management  false

                        address     172.20.8.124
                            ip-address     172.20.8.124
                            prefix-length  16
                            gateway        172.20.0.1
                        exit
                    exit
                exit
            exit

            node  conductornode2
                name              conductornode2
                asset-id          conductornode2

                device-interface  mgmt
                    name               mgmt
                    pci-address        0000:0b:00.0
                    forwarding         false

                    network-interface  mgmt-if
                        name        mgmt-if
                        global-id   2
                        type        fabric
                        management  false

                        address     172.20.8.125
                            ip-address     172.20.8.125
                            prefix-length  16
                            gateway        172.20.0.1
                        exit
                    exit
                exit
            exit
        exit
    exit
exit

admin@conductornode1.conductoresxi#




Issue if not interfaceno-forwarding

Image Added



https://www.juniper.net/documentation/us/en/software/session-smart-router/docs/bcp_conductor_deployment#conductor-redundancy


open 930/TCP and 4505-4506/TCP (used for salt) to allow a conductor to communicate to managed routers.

Open 443/TCP for the web UI, and 22/TCP for remote SSH


Image Added