FMS or Alarms in OcNOS
enable FMS | |
---|---|
FMS enable R2-OcNOS-POC19aug(config)#fault-management enable R2-OcNOS-POC19aug(config)#commit %% Warning : FMS requires logging level all to be configured to minimum 4, please configure accordingly R2-OcNOS-POC19aug(config)#logging level all 0 1 2 3 4 5 6 7 R2-OcNOS-POC19aug(config)#logging level all ? 0 emerg 1 alert 2 critical 3 error 4 oper-notify/debug-warn 5 oper-info/debug-notify 6 debug-info 7 debug-details <cr> | |
show alarms | |
show alarms R2-OcNOS-POC19aug#show alarm ? active Display Active alarms closed Display closed alarms history History of Alarms shelved Display shelved alarm types statistics Display alarms statistics transitions Display alarms transitions | |
clear alarms | |
fault-management flush-db | |
fault-management close CMM_MONITOR_VOLTAGE:Input_Voltage:PSU-0 | |