Digital Diagnostic Monitoring (DDM) commands
https://docs.ipinfusion.com/service-provider/#page/OcNOS-SP/Sysman_Cmds/DDM_CLIcmds.html
|
|
---|
show inter controllers |
Code Block |
---|
title | show inter controllers |
---|
collapse | true |
---|
| . . .
############################################################
Port Number : 0
Name : CISCO-INNOLIGHT
OUI : 0x44 0x7c 0x7f
Part No : TR-FC85S-NC2
Serial_Number : AT231720052
Identifier : QSFP28 Or Later
Ext. Identifier : Power Class 4 (3.5W Max)
CDR Present In TX
CDR Present In RX
Connector Type : MPO 1x12 (Multifiber Parallel Optic)
Ethernet/Ext-Eth Compliance : 100GBASE-SR4 or 25GBASE-SR
SONET Compliance :
FC link Length :
FC Transmitter Technology :
FC Transmission Media :
FC Speed :
Length SMF : 0 (Kilometers)
Length OM1 : 0 (Meters)
Length OM2 : 0 (Meters)
Length OM3 : 35 (X 2 Meters)
Length OM4 / Cable Assembly : 50 (X 1 Meters (For Copper or AOC) / X 2 Meters (for OM4))
Revision Level : 1B
Manufacturing Date : 230425 (yymmddvv, v=vendor specific)
Encoding Algorithm : 64B/66B
CC : 0x41
CC Ext. : 0xd1
Nominal BR : 255 (X 100 Mbps)
Max Case Temperature : 70.00C
Options Implemented : TX Input Equalization Fixed Programmable
RX Output Emphasis Fixed Programmable
RX Output Amplitude Fixed Programmable
TX CDR On/Off Controllable
RX CDR On/Off Controllable
Tx CDR Loss of Lock (LOL)
Rx CDR Loss of Lock (LOL)
Rx Squelch Disable
Rx Output Disable
Tx Squelch Disable
Tx Squelch
Page 2 Provided
Page 1 Provided
RATE_SELECT Fixed
TX_DISABLE
TX_FAULT
Tx Squelch To Reduce OMA
Tx Loss Of Signal (LOS)
Device Technology : No Wavelength Control
PIN Detector
Transmitter Not Tunable
Uncooled Transmitter Device
850nm VCSEL
wavelength : 850nm
Wavelength Tolerance : 10nm
DDM Support : Yes
############################################################
Port Number : 1
. . . |
|
|
|
|
|
---|
show inter ce0 transceiver details |
Code Block |
---|
title | show inter ce0 |
---|
collapse | true |
---|
| R7#show inter ce0 transceiver de
Codes: * Not Qualified By IP Infusion, ** Not Supported By Module, -- No Power, - Not Applicable
Intf DDM Temp AlertMax CritMax CritMin AlertMin
(Celsius) (Celsius) (Celsius) (Celsius) (Celsius)
---------------------------------------------------------------------------
ce0 Inactive* +31.02 +75.00 +73.00 -3.00 -5.00
Intf DDM Volt AlertMax CritMax CritMin AlertMin
(Volts) (Volts) (Volts) (Volts) (Volts)
---------------------------------------------------------------------------
ce0 Inactive* +3.297 +3.630 +3.470 +3.140 +2.970
Intf DDM Lane Curr AlertMax CritMax CritMin AlertMin
(mA) (mA) (mA) (mA) (mA)
-------------------------------------------------------------------------------------
ce0 Inactive* 1 +6.500 +15.000 +12.000 +2.000 +0.000
2 +6.500 +15.000 +12.000 +2.000 +0.000
3 +6.500 +15.000 +12.000 +2.000 +0.000
4 +6.500 +15.000 +12.000 +2.000 +0.000
Intf DDM Lane RxPwr AlertMax CritMax CritMin AlertMin
(dBm) (dBm) (dBm) (dBm) (dBm)
-------------------------------------------------------------------------------------
ce0 Inactive* 1 -1.658 +3.400 +2.400 -10.301 -12.299
2 -1.092 +3.400 +2.400 -10.301 -12.299
3 -0.881 +3.400 +2.400 -10.301 -12.299
4 -1.084 +3.400 +2.400 -10.301 -12.299
Intf DDM Lane TxPwr AlertMax CritMax CritMin AlertMin
(dBm) (dBm) (dBm) (dBm) (dBm)
-------------------------------------------------------------------------------------
ce0 Inactive* 1 -0.548 +3.400 +2.400 -7.600 -10.400
2 -0.484 +3.400 +2.400 -7.600 -10.400
3 -0.669 +3.400 +2.400 -7.600 -10.400
4 -0.584 +3.400 +2.400 -7.600 -10.400
Intf DDM Lane Tx Rx-LOS Tx-LOS
-------------------------------------------------------------
ce0 Inactive* 1 On Off Off
2 On Off Off
3 On Off Off
4 On Off Off
R7#
|
|
|
|
|
|
...