Skip to end of metadata
Go to start of metadata

You are viewing an old version of this page. View the current version.

Compare with Current View Page History

Version 1 Current »




show inter controllers
show inter controllers
. . . 
############################################################
Port Number                   : 0
Name                          : CISCO-INNOLIGHT
OUI                           : 0x44 0x7c 0x7f
Part No                       : TR-FC85S-NC2
Serial_Number                 : AT231720052
Identifier                    : QSFP28 Or Later
Ext. Identifier               : Power Class 4 (3.5W Max)
                                CDR Present In TX
                                CDR Present In RX
Connector Type                : MPO 1x12 (Multifiber Parallel Optic)
Ethernet/Ext-Eth Compliance   : 100GBASE-SR4 or 25GBASE-SR
SONET Compliance              :
FC link Length                :
FC Transmitter Technology     :
FC Transmission Media         :
FC Speed                      :
Length SMF                    : 0 (Kilometers)
Length OM1                    : 0 (Meters)
Length OM2                    : 0 (Meters)
Length OM3                    : 35 (X 2 Meters)
Length OM4 / Cable Assembly   : 50 (X 1 Meters (For Copper or AOC) / X 2 Meters (for OM4))
Revision Level                : 1B
Manufacturing Date            : 230425   (yymmddvv, v=vendor specific)
Encoding Algorithm            : 64B/66B
CC                            : 0x41
CC Ext.                       : 0xd1
Nominal BR                    : 255 (X 100 Mbps)
Max Case Temperature          : 70.00C
Options Implemented           : TX Input Equalization Fixed Programmable
                                RX Output Emphasis Fixed Programmable
                                RX Output Amplitude Fixed Programmable
                                TX CDR On/Off Controllable
                                RX CDR On/Off Controllable
                                Tx CDR Loss of Lock (LOL)
                                Rx CDR Loss of Lock (LOL)
                                Rx Squelch Disable
                                Rx Output Disable
                                Tx Squelch Disable
                                Tx Squelch
                                Page 2 Provided
                                Page 1 Provided
                                RATE_SELECT Fixed
                                TX_DISABLE
                                TX_FAULT
                                Tx Squelch To Reduce OMA
                                Tx Loss Of Signal (LOS)
Device Technology             : No Wavelength Control
                                PIN Detector
                                Transmitter Not Tunable
                                Uncooled Transmitter Device
                                850nm VCSEL
wavelength                    : 850nm
Wavelength Tolerance          : 10nm
DDM Support                   : Yes

############################################################
Port Number                   : 1
. . .




show inter ce0 transceiver details
show inter ce0
R7#show inter ce0 transceiver de
Codes:  * Not Qualified By IP Infusion,  ** Not Supported By Module,  -- No Power,  - Not Applicable

Intf       DDM        Temp       AlertMax   CritMax    CritMin    AlertMin
                      (Celsius)  (Celsius)  (Celsius)  (Celsius)  (Celsius)
---------------------------------------------------------------------------
ce0        Inactive*  +31.02     +75.00     +73.00     -3.00      -5.00

Intf       DDM        Volt       AlertMax   CritMax    CritMin    AlertMin
                      (Volts)    (Volts)    (Volts)    (Volts)    (Volts)
---------------------------------------------------------------------------
ce0        Inactive*  +3.297     +3.630     +3.470     +3.140     +2.970

Intf       DDM        Lane       Curr       AlertMax   CritMax    CritMin    AlertMin
                                 (mA)       (mA)       (mA)       (mA)       (mA)
-------------------------------------------------------------------------------------
ce0        Inactive*  1          +6.500     +15.000    +12.000    +2.000     +0.000
                      2          +6.500     +15.000    +12.000    +2.000     +0.000
                      3          +6.500     +15.000    +12.000    +2.000     +0.000
                      4          +6.500     +15.000    +12.000    +2.000     +0.000

Intf       DDM        Lane       RxPwr      AlertMax   CritMax    CritMin    AlertMin
                                 (dBm)      (dBm)      (dBm)      (dBm)      (dBm)
-------------------------------------------------------------------------------------
ce0        Inactive*  1          -1.658     +3.400     +2.400     -10.301    -12.299
                      2          -1.092     +3.400     +2.400     -10.301    -12.299
                      3          -0.881     +3.400     +2.400     -10.301    -12.299
                      4          -1.084     +3.400     +2.400     -10.301    -12.299

Intf       DDM        Lane       TxPwr      AlertMax   CritMax    CritMin    AlertMin
                                 (dBm)      (dBm)      (dBm)      (dBm)      (dBm)
-------------------------------------------------------------------------------------
ce0        Inactive*  1         -0.548     +3.400     +2.400     -7.600     -10.400
                      2         -0.484     +3.400     +2.400     -7.600     -10.400
                      3         -0.669     +3.400     +2.400     -7.600     -10.400
                      4         -0.584     +3.400     +2.400     -7.600     -10.400

Intf       DDM        Lane       Tx         Rx-LOS     Tx-LOS
-------------------------------------------------------------
ce0        Inactive*  1          On         Off        Off
                      2          On         Off        Off
                      3          On         Off        Off
                      4          On         Off        Off
R7#





  • No labels